Product Details
Description
Huawei s5731-s24t4x Series S5700 Switch
Overview of Huawei s5731-s24t4x Series S5700 Switch
The Huawei CloudEngine series switches were developed based on next-generation high-performing hardware and the Huawei Versatile Routing Platform (VRP). The CloudEngine supports simplified operations and maintenance (O&M), intelligent stack (iStack), flexible Ethernet networking. It also provides enhanced Layer 3 features and mature IPv6 features. The CloudEngine can be used in various scenarios. For example, it can be used as an access or aggregation switch on a campus network or as an access switch for Metropolitan Area Network.
This Switch is built on Huawei’s unified Versatile Routing Platform (VRP), CloudEngine switches provide enhanced Layer 3 features, simplified Operations & Maintenance (O&M), Intelligent Stack (iStack) technology — allowing multiple stacking-capable switches to function as a single logical switch — flexible Ethernet networking, and mature Internet Protocol version 6 (IPv6) features.
CloudEngine supports zero-touch deployment, replacement of faulty devices without additional configuration, USB-based deployment, batch configuration, and batch remote upgrade. The capabilities facilitate device deployment, upgrade, service provisioning, and other management and maintenance operations, and also greatly reduce O&M costs. The CloudEngine can be managed using SNMP v1/v2c/v3, CLI, web-based network management system, or SSH v2. 0. Additionally, it supports RMON, multiple log hosts, port traffic statistics collection, and network quality analysis, which facilitate network optimization and reconstruction.
The series is widely used in a range of scenarios, including enterprise campus access and aggregation, as well as data center access.
Specification of Huawei s5731-s24t4x Series S5700 Switch
Item | Description |
Part number | 02353AHU |
02353AHU-001 | |
Memory (RAM) | 4 GB |
Flash | 1 GB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) | 57.73 years |
Mean time to repair (MTTR) | 2 hours |
Availability | > 0.99999 |
Service port surge protection | Common mode: ±6 kV |
Power supply surge protection | Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode |
Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode | |
Weight (with packaging) | 8.4 kg (18.52 lb) |
Stack ports | 10GE SFP+ ports on the front panel |
Maximum power consumption (100% throughput, full speed of fans) | 114 W |
Typical power consumption (30% of traffic load, tested according to ATIS standard) | 88 W |
Operating temperature | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) | < 57.5 dB(A) |
Relative humidity | 5% to 95%, noncondensing |
Operating altitude | 0-5000 m (0-16404 ft.) |
Certification | EMC certification |
Safety certification | |
Manufacturing certification | |
Dimensions (H x W x D) | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.4 in. x 17.7 in.) | |
Rated voltage range | AC input: 100 V AC to 240 V AC, 50/60 Hz |
High-Voltage DC input: 240 V DC | |
DC input: -48 V DC to -60 V DC | |
Maximum voltage range | AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz |
High-Voltage DC input: 190 V DC to 290 V DC | |
DC input: -38.4 V DC to -72 V DC |
Indicator Description
The S5731-S24T4X has similar indicators to those on the S5731-S48P4X except that the S5731-S24T4X does not have a PoE mode indicator. For details, see Indicator Description.
Power Supply Configuration
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with natural heat dissipation and the power modules with fan cannot be used at the same time.
Heat Dissipation
The S5731-S24T4X uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.
To know more about this switch, Visit the Huawei Website.