Product Details
JH324A
Model: | JH324A – HP 5130 HI Switches |
Detail: | HPE 5130 48G 4SFP+ 1-slot HI Switch |
Description
JH324A Specifications |
|
Physical specifications |
|
Type |
HPE 5130 48G 4SFP+ HI with 1 Interface Slot Switch |
Dimensions (H x W x D) |
4.37 x 44.0 x 36 cm (1.72 x 17.32 x 14.17 in) (1U height) |
Weight |
7.5 kg (16.53 lb) |
System specifications |
|
1000 Mb Latency |
< 5 µs |
10 Gbps Latency |
< 3 µs |
Throughput |
up to 190.5 Mpps |
Routing/Switching capacity |
256 Gbps |
Routing table size |
32768 entries (IPv4), 16384 entries (IPv6) |
MAC address table size |
32768 entries |
I/O ports and slots |
48 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Media Type: Auto-MDIX; Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only; Ports 1 – 8 support MACSec 4 SFP+ 10GbE ports 1 port expansion module slot Supports a maximum of 6 SFP+ ports or 2 1/10GBASE-T ports, with optional module |
Power supplies |
2 power supply slots 1 minimum power supply required (ordered separately) |
Fan tray |
Airflow direction is Front (port side) to Back (power cord side) |
Memory and processor |
2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash |
Mounting and enclosure |
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware include |
Electrical specifications |
|
Frequency |
50/60 Hz |
Maximum heat dissipation |
419 BTU/hr (442.04 kJ/hr), Ranges from 201 BTU/hr to 443 BTU/hr, depending on power supply configuration |
Voltage |
100 – 240 V ac, rated (90 – 264 V ac, max) -48 to -60 V dc, rated (-36 to -72 V dc, max) (depending on power supply chosen) |
Maximum power rating |
150 W |
Idle power |
70 W |
PoE power |
N/A |
Environmental specifications |
|
Operating temperature |
0°C to 45°C(32°F to 113°F) |
Operating relative humidity |
10% to 90%, noncondensing |
Nonoperating/Storage temperature |
-40°C to 70°C (-40°F to 158°F) |
Nonoperating/Storage relative humidity |
5% to 95%, noncondensing |
Acoustic |
Low-speed fan: 49.9 dB, High-speed fan: 64.8 dB; ISO 7779 |
Safety certifications |
|
Safety |
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; ROHS Compliance; AS/NZS 60950-1; GB 4943; EAC (EurAsian Conformity Certification) |
Emissions |
EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN 61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3- 2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000- 4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000- 4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A |
Immunity |
Generic EN 55024 ESD EN300 386 |
Management |
IMC – Intelligent Management Center, Command-line interface, Web browser, SNMP manager |