Model: | Huawei OptiX OSN 1800 II Enhanced – Huawei OptiX OSN 1800 |
Detail: | Huawei OptiX OSN 1800 II Enhanced chassis, supports full-granularity cross-connections and multiplexing, a maximum of 200 Gbit/s OTN capacity, 160Gbit/s packet capacity, 50 Gbit/s SDH higher-order and 20 Gbit/s SDH lower-order capacities, and supports ODUk (k = 0, 1, 2, 2e, C2, flex) |
Description
Huawei OptiX OSN 1800 I Enhanced Specification |
||
Dimensions (mm) | 88 x 442 x 220 (H x W x D) (excluding mounting ears) | |
Number of service board slots | 6 | |
Optical-layer cross-connect capability | 1-degree to 9-degree ROADM | |
Device capacity | OTN | • 160 Gbit/s OTN capacity (OTN+PKT+SDH)
• 200 Gbit/s OTN capacity (OTN+SDH) |
Packet | • Packet switching capacity: 160 Gbit/s (128 bytes)
• Packet processing capability: 150 Mpps (64 bytes) |
|
TDM | 50 Gbit/s higher-order capacity, 20 Gbit/s lower-order capacity | |
Maximum number of wavelengths | DWDM | 80 |
CWDM | 8 | |
Maximum rate per channel | 200 Gbit/s | |
Supported service type | SDH service (STM-1/4/16/64), PDH service (E1/T1/E3/T3/E4)
OTN service (OTU1/2/2e/4), Ethernet service (FE/GE/10GE/40GE/100GE) CPRI service, OBSAI service, PCM service SAN service, video, and others |
|
PCM interface | FXS/FXO, 2/4 line audio+E&M, G.703 64 kbit/scodirectional,V.35/V.24(synchronous/asynchronous RS232)/X.21,RS449(RS423A/RS422A)/RS530/RS530A/RS485/Dry Contact | |
Network application | Pure packet networking, pure OTN networking, and pure TDM networking
MS-OTN networking (OTN+packet+TDM) and OTN+TDM networking |
|
Redundancy
and protection |
Network-level protection (OTN) | Client 1+1 protection, intra-board 1+1 protection, ODUk SNCP, optical line protection, tributary SNCP, and LPT |
Network-level protection (packet) | Tunnel APS, PW APS/FPS, LPT, LAG, ERPS, LMSP, packet SNCP, and MRPS | |
Network-level protection (TDM) | • SDH protection: SNCP, linear MSP, TPS, and ring MSP
• EoS protection: LAG, DLAG, LCAS, LPT, and STP/RSTP • PCM protection: E1 SNCP, 64K SNCP, and hitless protection switching |
|
Equipment-level
protection |
• Backup of cross-connect, system control, and clock units
• Power supply backup • Fan backup |
|
Easy O&M | OD and FD systems | |
Synchronization | • Physical-layer clock (OTN&packet&SDH)
• IEEE 1588v2 (OTN&packet) • ITU-T G.8275.1/G.8273.2 (OTN&packet) |
|
Power supply | • DC power input Standard operating voltage: –48 V DC/–60 V DC |