Free shipping on all UAE order

All Products
More Categories Close Menu

15+ Years Of Experience

  • Gear Net Technologies LLC
  • sira-removebg-preview
sira-removebg-preview

Product Details

UA13MCU

AED3,791.00

< tbody >

Model: Huawei Contact Center UAP3300 series UA13MCU
Detail: Huawei UA13MCU Contact Center UAP3300 Main Control Unit
Chat With GNTME LLC

Share this product

Description

UAP3300 Specifications

Power Distribution System

100 V to 240 V AC power distribution system

maximum output power

275 W

Dimensions(W*D*H mm)

Shelf: 436*420*264

Main control board: 367*280

Interface board: 170*280

UAP-PTS: 440*342*43

Rated Voltage

110 V or 220 V AC

e Input Voltage Range

100 V-240 V AC

Power Frequency Range

50 Hz or 60 Hz

Maximum Power Consumption in Full Configuration

About 430 W

System Capacity

·The IVR of the UAP3300 system can connect to 23,040 users.

·The UAP3300 provides a 30,720-channel trunk.

·The UAP3300 provides up to 7680 agents.

Performance Indexes

·When 30 calls are initiated concurrently, the average put-through duration is shorter than 1.5 seconds.

·The put-through rate of calls is equal to or greater than 99.999%. The average duration for dynamically switching voice encoding is shorter than 60 milliseconds.

·The mean time between failures (MTBF) is 10 years.

·The BHCA for each UAP3300 is 4,000,000.

EMC

·EN 55022: 1998 + A1: 2000 + A2: 2003

·EN 55024: 1998 + A1: 2001 + A2: 2003

·CISPR 22: 2003

·CISPR 24: 1997 + A1: 2001 + A2: 2002

·IEC 61000-3-2: 2001/EN 61000-3-2: 2000

·IEC 61000-3-3: 2002/EN 61000-3-3: 1995 + A1: 2001

·ETSI EN 300 386V1.3.3: 2005 l AS/NZS CISPR 22: 2004

·ANSI C63.4: 2003

·IEC 61000-4-2: 2001/EN 61000-4-2:1995  IEC 61000-4-3: 2006/EN 61000-4-3: 2002

·IEC 61000-4-4: 2004/EN 61000-4-4: 2004

·IEC 61000-4-5: 2005/EN 61000-4-5: 1995

·IEC 61000-4-6: 2006/EN 61000-4-6: 1996

·IEC 61000-4-11: 2001/EN 61000-4-11: 1995

Security Specifications

IEC 60950-1

EN 60950-1

UL 60950-1

CSA C22.2 No 60950-1

AS/NZS 60950-1

BS EN 60950-1

GB4943

Environment Requirements

Storage temperature: -40ºC to +70ºC

Temperature for long-term running: 0ºC to 45ºC

Temperature for short-term running: -5ºC to +55ºC

Humidity: 5%-95% relative humidity, no condensing

Altitude: not higher than 3000 meters (The UAP3300 can keep the same performance within the altitude of 3000 meters.)