Model: | N9K-C93120TX – Cisco Nexus 9000 Series |
Detail: | Nexus 9300 with 96p 100M/1/10G-T and 6p 40G QSFP |
PDF Attachment:
Description
N9K-C93120TX – Cisco Nexus 9000 Series in Dubai, UAE. Associations wherever perceive that changing application conditions are making new requests for the IT framework that upholds them. Application jobs are conveyed across a blend of virtualized and non virtualized worker and capacity foundation, requiring an organizational framework that gives reliable availability, security, and permeability across a scope of exposed metal, virtualized and distributed computing conditions:
The Cisco Nexus 9300 stage switches are high-thickness, nonblocking, low-power-burning-through switches intended for ToR, MoR, and end-of-column (EoR) organizations in big business server farms, specialist co-op offices, and enormous virtualized and distributed computing conditions.
The Cisco Nexus 93120TX Switch is a 2RU switch that underpins 2.4 Tbps of data transfer capacity and more than 1500 mpps across 96 fixed 1/10G BASE-T ports and 6 fixed 40-Gbps QSFP ports. The Cisco Nexus 9300 stage can uphold numerous racks (or units) of thick 1RU workers. The Cisco Nexus 93120TX can give 10 Gigabit Ethernet. Buy Related products like C1-N9K-C93180-B18Q.
Main Features :
- Switch
- L3
- managed
- 96 x 10GBase-T + 6 x 40 Gigabit QSFP+
- desktop
- rack-mountable
N9K-C93120TX Specification |
|
Ports | 96 fixed 1/10GBASE-T and 6 QSFP+ ports |
Supported speeds | 100 Megabit Ethernet and 1/10 Gigabit Ethernet speeds |
40 Gigabit Ethernet uplink ports | 6 fixed QSFP+ ports |
Advanced QSFP+ optics enable connectivity using existing 10 Gigabit Ethernet fiber.
The switch offers 25 MB of additional packet buffer space shared with all ports for more resilient operations. |
|
Power supplies (up to 2) | 1200W AC, 930W DC, or 1200W HVAC/HVDC |
Typical power (AC) | 542W |
Maximum power (AC) | 948W |
Input voltage (AC) | 100 to 240V
*PSU redundancy is not supported when used in 110V |
Input voltage (HVAC) | 200 to 277V |
Input voltage (DC) | -40V to -72V DC (min-max)
-48V to -60V DC (nominal) |
Input voltage (HVDC) | –240 to –380V |
Frequency (AC) | 50 to 60 Hz |
Fans | 2 |
Physical (H x W x D) | 3.5 x 17.5 x 22.5 in. (8.9 x 44.5 x 57.1 cm) |
RoHS compliance | Yes |
Weight | 26 lb (11.8 kg) (without power supplies, fans, or uplink module) |