Product Details
N3K-C3232C
AED31,710.00
Model: | N3K-C3232C – Nexus Switches Power Supply |
Detail: | Nexus 3232C 32 x 100G,1RU switch |
Description
N3K-C3232C Specification |
||
Physical |
· 1RU fixed form-factor switch · 32 QSFP28 ports; each supports native 100 Gigabit Ethernet and 4 x 25 Gigabit Ethernet modes · 2 redundant power supplies · 4 redundant (3+1) fans · Management, console, and USB flash-memory ports |
|
Performance |
· 6.4-Tbps switching capacity · Forwarding rate of up to 3.3 bpps · Line-rate traffic throughput (both Layer 2 and 3) on all ports · Configurable maximum transmission unit (MTU) of up to 9216 bytes (jumbo frames) |
|
Hardware tables and scalability |
Number of MAC addresses |
40,000 |
Number of VLANS |
4096 |
|
Number of spanning-tree instances |
· RSTP: 512 · MSTP: 64 |
|
Number of ACL entries |
· 6000 ingress · 1000 egress |
|
Routing table |
· Maximum number of longest-prefix-match (LPM) routes: 128,000 · Maximum number of IP host entries:72,000 · Maximum number of MAC address entries: 136,000 · Maximum number of Layer 3 multicast entries: 64,000 |
|
Number of EtherChannels |
256 (with vPC) |
|
Latency |
~450ns |
|
Number of ports per EtherChannel |
32 |
|
Buffer size |
16 MB shared |
|
System memory |
8 GB |
|
Boot-flash memory |
64 GB |
|
Power |
Frequency |
50 to 60 Hz |
Power-supply types |
· AC (forward and reverse airflow) |
|
Typical operating power |
205 watts (W) |
|
Maximum power |
402W |
|
AC PSUs · Input voltage · Frequency · Efficiency |
· 100 to 240 VAC · 50 to 60 Hz · 89 to 91% at 220V |
|
Power-supply efficiency |
89 to 91% at 220V |
|
Typical heat dissipation |
700 BTU/hr |
|
Maximum heat dissipation |
1371 BTU/hr |
|
Cooling |
· Forward and reverse airflow schemes ◦ Forward airflow: Port-side exhaust (air enters through fan tray and power supplies and exits through ports) ◦ Reverse airflow: Port-side intake (air enters through ports and exits through fan tray and power supplies) · Redundant fans · Hot swappable (must swap within 1 minute) |
|
Sound |
Measured sound power (maximum) · Fan speed: 40% duty cycle · Fan speed: 70% duty cycle · Fan speed: 100% duty cycle |
· 66.1 dBA · 70.6 dBA · 76.9 dBA |
Environment |
Dimensions (height x width x depth) |
1.72 x 17.3 x 22.4 in. (4.4 x 43.9 x 56.8 cm) |
Weight |
22.2 lb (10.06 kg) |
|
Temperature: Operating |
32 to 104°F (0 to 40°C) |
|
Temperature: Storage |
-40 to 158°F (-40 to 70°C) |
|
Relative humidity: Operating |
· 10 to 85% noncondensing · Up to 5 days at maximum (85%) humidity · Recommend ASHRAE data center environment |
|
Relative humidity: Storage |
5 to 95% noncondensing |
|
Altitude |
0 to 10,000 ft (0 to 3000m) |