Product Details
Huawei OptiX OSN 6800
< tbody >
Model: | Huawei OptiX OSN 6800 – Huawei OptiX OSN 6800 |
Detail: | Huawei OptiX OSN 6800 supports 40 Gbit/s, 100 Gbit/s and 200 Gbit/s line rates and a 360G bit/s cross-connect capacity, provides power saving, and high reliability and maintainability |
Description
Huawei OptiX OSN 6800 Specification |
||
Dimensions (mm) | 497 (W) x 295 (D) x 400 (H) | |
Number of slots for service boards | 17 | |
Switch | Optical | 1 to 20-degree ROADM |
Electrical | • 180G GE
• 360G 10GE/ODUk(k=1, 2, 2e) |
|
Wavelength (max) | DWDM: 80-ch, CWDM: 8-ch | |
Wavelength range
|
DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1)
CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2) |
|
Max. rate per channel | 100 Gbit/s (OTU4) | |
Service types supported | SDH, SONET, Ethernet, SAN, OTN, Video | |
Line rate | 2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s | |
Supported pluggable optical modules | eSFP, SFP+, XFP, CFP | |
Max. capacity per PID group | 120 Gbit/s | |
Topology
|
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, me | |
Redundancy and protection | Network level protection (OTN)
|
Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, MS SNCP, ODUk SPRing protection, OWSP, board-Level protection |
Network level protection (Ethernet) | DBPS, DLAG, ERPS, LAG, LPT, MSTP, STP and RSTP, VLAN SNCP | |
Equipment level protection
|
Power redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy | |
Optical power management | ALS, AGC, ALC, APE, IPA, OPA | |
Synchronization
|
• Synchronous Ethernet clock
• IEEE 1588v2 • 2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source •External time source (1PPS+TOD) |
|
ASON | Optical-Layer ASON | |
Nominal working voltage | -48 V DC/-60 V DC | |
Maximum subrack power consumption | 1350 W | |
Operation environment
|
Subrack temperature:
• Long-term operation: 5°C (41 °F) to 45°C (113 °F) • Short-term operation: -5°C (23 °F) to 55°C (131 °F) Relative humidity: • Long-term operation: 5% to 85% • Short-term operation: 5% to 95% |
|
Mean time to repair (MTTR) | 4 hours | |
Mean time between failures (MTBF) | 51.64 years |