Huawei 6857E-48S6CQ Cloud Engine
Specification of Huawei 6857E-48S6CQ Cloud Engine:
CPU | 4-core, 1.6 GHz |
Memory | DRAM: 4 GB |
NOR Flash | 128 MB |
SSD Flash | 8 GB |
USB | Supported |
Static power consumption [W] | 106 W |
Static heat dissipation [BTU/hour] | 362 BTU/hour |
Maximum power consumption [W] | 318 W |
Features of Huawei 6857E-48S6CQ Cloud Engine:
Item | Description |
Installation Type | Cabinet Installation |
CPU | 4-core, 1.6 GHz |
Memory | DRAM: 4 GB |
NOR Flash | 128 MB |
SSD Flash | 8 GB |
USB | Supported |
Power supply mode | · AC
· DC · HVDC |
Console port | RJ45 |
Downlink Service interface | 48*10GE SFP+ (Note: The 10GE LRM/80KM linear optical module and 1000base-X auto-negotiation are not supported. 1GE optical modules can be used for interconnection only when auto-negotiation is disabled on the peer port.) |
Uplink Service interface | 6*100GE QSFP28 (Note: 1. 100GE interfaces are compatible with 40GE; 2. 100GE interfaces do not support splitting into 4x25GE and 4x10GE.) |
Service port supporting the stack function | 10GE optical ports and 100GE optical ports |
RTC | Supported |
Typical power consumption [W] | · 148 W (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
· 185 W (50% throughput, short-distance optical modules on all optical ports, dual power modules) |
Typical heat dissipation [BTU/hour] | · 505 BTU/hour (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
· 631 BTU/hour (50% throughput, short-distance optical modules on all optical ports, dual power modules) |
Static power consumption [W] | 106 W |
Static heat dissipation [BTU/hour] | 362 BTU/hour |
Maximum power consumption [W] | 318 W |
Maximum heat dissipation | 1085 BTU/hour |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | · 600 W AC&240 V DC power module : AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
· 1000 W DC power module : -48V DC to -60V DC · 1200 W high-voltage DC power module: 240 V DC to 380V DC |
Input voltage range [V] | · 600 W AC&240 V DC power module : AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC
· 1000 W DC power module : -38.4 V DC to -72 V DC · 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A] | · 600 W AC&240 V DC power module : 8 A (100 V AC to 240 V AC); 4 A (240 V DC)
· 1000 W DC power module : 30 A (-48 V DC to -60 V DC) · 1200 W high-voltage DC power module: 8 A |
Rated output power [W] | · 600 W AC&240 V DC power module : 600 W
· 1000 W DC power module : 1000 W · 1200 W high-voltage DC power module: 1200 W |
Certification | · Safety standards compliance
· EMC standards compliance · Environmental standards compliance |
Power supply surge protection [kV] | · AC: 6 kV in common mode and 6 kV in differential mode
· DC: 4 kV in common mode and 2 kV in differential mode · HVDC: 4 kV in common mode and 2 kV in differential mode |
Types of fans | Pluggable |
Number of fans | 4 |
Redundant fans | The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Port-side intake or exhaust, depending on the fan modules and power modules. |
Availability | 0.9999961836 |
MTBF [year] | 49.35 years |
MTTR [hour] | 1.65 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | · Front-to-back airflow: average 50 dBA (maximum: 54 dBA)
· Back-to-front airflow: average 53 dBA (maximum: 57 dBA) |
Noise at high temperature (40°C, sound pressure) [dB(A)] | · Front-to-back airflow: average 69 dBA (maximum: 73 dBA)
· Back-to-front airflow: average 72 dBA (maximum: 77 dBA) |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0 to 1800 m (0 to 5906 ft.) |
Storage altitude [m (ft.)] | < 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |