Free shipping on all UAE order

All Products
More Categories Close Menu

15+ Years Of Experience

  • Gear Net Technologies LLC
  • sira-removebg-preview
sira-removebg-preview

Product Details

Sale!

Huawei 6857e-48s6cq Cloud Engine Best Price

Original price was: $36,300.00.Current price is: $3,251.00.

CloudEngine 6800 is well suited to both the core and aggregation layers, and is fully compatible with CloudEngine 16800 and 12800 series switches, enabling enterprises to build scalable, simplified, open, and secure networks.

Chat With GNTME LLC
Category: Tags: ,

Share this product

Description

Huawei 6857E-48S6CQ Cloud Engine

Huawei 6857E-48S6CQ Cloud Engine

Specification of Huawei 6857E-48S6CQ Cloud Engine:

CPU 4-core, 1.6 GHz
Memory DRAM: 4 GB
NOR Flash 128 MB
SSD Flash 8 GB
USB Supported
Static power consumption [W] 106 W
Static heat dissipation [BTU/hour] 362 BTU/hour
Maximum power consumption [W] 318 W

Features of Huawei 6857E-48S6CQ Cloud Engine:

Item Description
Installation Type Cabinet Installation
CPU 4-core, 1.6 GHz
Memory DRAM: 4 GB
NOR Flash 128 MB
SSD Flash 8 GB
USB Supported
Power supply mode ·         AC

·         DC

·         HVDC

Console port RJ45
Downlink Service interface 48*10GE SFP+ (Note: The 10GE LRM/80KM linear optical module and 1000base-X auto-negotiation are not supported. 1GE optical modules can be used for interconnection only when auto-negotiation is disabled on the peer port.)
Uplink Service interface 6*100GE QSFP28 (Note: 1. 100GE interfaces are compatible with 40GE; 2. 100GE interfaces do not support splitting into 4x25GE and 4x10GE.)
Service port supporting the stack function 10GE optical ports and 100GE optical ports
RTC Supported
Typical power consumption [W] ·         148 W (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)

·         185 W (50% throughput, short-distance optical modules on all optical ports, dual power modules)

Typical heat dissipation [BTU/hour] ·         505 BTU/hour (50% throughput, SFP+ high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)

·         631 BTU/hour (50% throughput, short-distance optical modules on all optical ports, dual power modules)

Static power consumption [W] 106 W
Static heat dissipation [BTU/hour] 362 BTU/hour
Maximum power consumption [W] 318 W
Maximum heat dissipation 1085 BTU/hour
Number of power modules 2
Redundant power supply 1+1 backup
Rated input voltage [V] ·         600 W AC&240 V DC power module : AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC

·         1000 W DC power module : -48V DC to -60V DC

·         1200 W high-voltage DC power module: 240 V DC to 380V DC

Input voltage range [V] ·         600 W AC&240 V DC power module : AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC

·         1000 W DC power module : -38.4 V DC to -72 V DC

·         1200 W high-voltage DC power module: 190 V DC to 400 V DC

Maximum input current [A] ·         600 W AC&240 V DC power module : 8 A (100 V AC to 240 V AC); 4 A (240 V DC)

·         1000 W DC power module : 30 A (-48 V DC to -60 V DC)

·         1200 W high-voltage DC power module: 8 A

Rated output power [W] ·         600 W AC&240 V DC power module : 600 W

·         1000 W DC power module : 1000 W

·         1200 W high-voltage DC power module: 1200 W

Certification ·         Safety standards compliance

·         EMC standards compliance

·         Environmental standards compliance

Power supply surge protection [kV] ·         AC: 6 kV in common mode and 6 kV in differential mode

·         DC: 4 kV in common mode and 2 kV in differential mode

·         HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fans Pluggable
Number of fans 4
Redundant fans The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Air cooling
Airflow direction Port-side intake or exhaust, depending on the fan modules and power modules.
Availability 0.9999961836
MTBF [year] 49.35 years
MTTR [hour] 1.65 hours
Noise at normal temperature (27°C, sound pressure) [dB(A)] ·         Front-to-back airflow: average 50 dBA (maximum: 54 dBA)

·         Back-to-front airflow: average 53 dBA (maximum: 57 dBA)

Noise at high temperature (40°C, sound pressure) [dB(A)] ·         Front-to-back airflow: average 69 dBA (maximum: 73 dBA)

·         Back-to-front airflow: average 72 dBA (maximum: 77 dBA)

Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH] 5% RH to 95% RH, noncondensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F) at an altitude of 0 to 1800 m (0 to 5906 ft.)
Storage altitude [m (ft.)] < 5000 m (16404 ft.)
Storage relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)] -40°C to +70°C (-40°F to +158°F)

Learn More about this Cloud Engine from Huawei Website.

Visit Our Website for products with the best quality and price.