Product Details
C8S45A
Model: | C8S45A – Brocade 16Gb/16c Embedded SAN Switch |
Detail: | Brocade 16Gb/16c Embedded SAN Switch |
Description
Brocade 16Gb SAN Switch for HPE BladeSystem c-Class Specification |
|||
Fibre Channel ports |
16 Internal (downlink) ports; 12 External (uplink) ports – universal (E, F, N, D) ports |
||
Performance |
16 Gbps line speed, full duplex |
||
Switch core |
Non-blocking |
||
Fabric latency |
700 nSec. Latency increases as input port speed is lower than the output port speed. |
||
Maximum frame size |
2112-byte payload |
||
Classes of service |
Class 2, Class 3, Class F (inter-switch frames) |
||
Port types |
D_Port (Diagnostic port), E_Port, F_Port; optional port type control |
||
Data traffic types |
Fabric switches supporting unicast |
||
Media types |
Hot-pluggable, B-Series Branded Small Form Factor Pluggable (SFP), LC connector; Short-Wave Laser (SWL), Long-Wave Laser (LWL); Extended Long-Wave Laser (ELWL); distance depends on fiber-optic cable and port speed. Supports SFP (4/2/1 Gbit/sec) and/or SFP+ (8/4/2 Gbit/sec) optical transceivers. |
||
Laser |
Short-wave, long-wave, and extended long wave laser transceivers (SFP’s) are supported |
||
Fabric services |
Simple Name Server, Registered State Change Notification (RSCN). Includes Advanced WebTools Enhanced group Management and Advanced Zoning. Optional fabric services include: Adaptive Networking, Fabric Watch, ISL Trunking, Advanced Performance Monitoring, and Extended Fabrics. |
||
Options |
SFP media, port upgradeable licensing, advanced management software licensing |
||
Supported software |
Telnet, SNMP (FE MIB, FC Management MIB), HPE Systems Insight Manager, HPE Storage Essentials, HPE Onboard Administrator for BladeSystem, Advanced WebTools, Enhanced Group Management, , Advanced Zoning, SAN Network Advisor, Fabric Watch, and Advanced Performance Monitoring |
||
Management access |
WebTools, SMI-s provider, SNMP, Telnet, and Secure Telnet |
||
Diagnostics |
Cable diagnostic (D_Port), including electrical/optical loopback, link traffic/latency/distance |
||
Dimensions |
Depth |
10.57 in. |
|
Height |
1.1 in. |
||
Width |
7.59 in. |
||
Weight |
Approx. 3.3 lb – without media |
||
Environment |
System Inlet Temperature |
Operating |
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305m (1.8°F per every 1000ft) above sea level to a maximum of 3050m (10,000ft), no direct sustained sunlight. Maximum rate of change is 10°C/Hr (18°F/Hr ). The upper limit may be limited by the type and number of options installed. |
Non-operating |
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/Hr (36°F/Hr). |
||
Relative Humidity |
Operating |
10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. |
|
Non-operating |
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. |
||
Altitude |
Operating |
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
|
Non-operating |
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). |
||
Vibration |
Operating |
1 G, 10-500 Hz, 60 minutes per axis |
|
Non-operating |
2 G, 10-500 Hz, 30 minutes |
||
Shock |
Operating |
Half-sine-wave shock, 40 G, 2 ms duration, in each direction of three mutually perpendicular axes. |
|
Non-operating |
Half-sine-wave shock, 140 G, 2 ms duration, in each direction of three mutually perpendicular axes; and square-wave shock up to 80 G, 180 inches/s velocity change, in each direction of three mutually perpendicular axes. |